Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
Status:
Valid
Buy this standard
StandardSwedish standard
·
SS-EN 16450:2017
Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions
In order to be in compliance with EU Air Quality Directive requirements, the reference methods given in the Directive 2008/50/EC [1] for the measurement of mass concentrations of particulate matter are not commonly used for operation in routine monitoring networks. These networks usually apply automated continuous measurement systems (AMS), such as those based on the use of oscillating microbalances, ß-ray attenuation, or in-situ optical methods. Such AMS are typically capable of producing 24-hour average measurement values over a measurement range up to 1 000 µg/m3 and 1-hour average measurement values up to 10 000 µg/m3, if applicable, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling. The 1-hour average values may be used for: a) direct information of the public; b) aggregation to produce daily or yearly average concentration values for regulatory reporting purposes. Directive 2008/50/EC allows the use of such systems after demonstration of equivalence with the reference method, i.e. after demonstration that these systems meet the Data Quality Objectives for continuous measurements. Guidelines for the demonstration of equivalence are given in Reference [2]. This European Standard lays down the minimum performance requirements and test procedures for the type approval of appropriate AMS for particulate matter. This includes the evaluation of its equivalence with the reference method as laid down in Directive 2008/50/EC. Further, this European Standard describes minimum requirements for ongoing quality assurance – quality control (QA/QC) of AMS deployed in the field. These requirements are necessary to ensure that uncertainties of measured concentrations are kept within the required limits during extended periods of continuous monitoring in the field, and include procedures for maintenance, calibration and control checks. Additional procedures are described that determine whether an instrument’s equivalence ...
Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions